Fluke 5502a extended specifications

WebFluke 5502A Operator's Manual (378 pages) Multi-Product Calibrator Brand: Fluke Category: Test Equipment Size: 10.1 MB Table of Contents Table of Contents 5 Introduction and Specifications 17 Introduction 19 Safety Information 20 Overload Protection 22 Operation Overview 22 Local Operation 22 Remote Operation (RS-232) 22 WebThe 5522A provides reverse power protection, immediate output disconnection, and/or fuse protection on the output terminals for all functions. This protection is for applied external voltages up to ±300 V peak. Rugged carrying case enables safe transport and efficient onsite calibration

Fluke 5522A Alternatives - Page 1

Web©2000 Fluke Corporation Rev. C-7/2000 Resolution J, K, T, E, L, N, U 0.1°C, 0.1°F B, R, S 1°C, 1°F Notes Accuracy specifications include 0.2°C cold junction uncertainty. Thermocouple Measure or Source J -200 to 0°C1.0°C 0 to 1200°C0.7°C K -200 to 0°C1.2°C 0 to 1370°C0.8°C T -200 to 0°C1.0°C 0 to 400°C0.8°C E -200 to 0°C0.9°C ... Web17 rows · The 5502A calibrator covers many of the most common items in your workload, including: Handheld ... portable chamber https://qtproductsdirect.com

5500A Operator Manual - Fluke Cal

Web5 Fluke Calibration 5520A Multi-Product Calibrator Extended Specifications 4 Fluke Corporation Fluke 5520A Extended Specifications DC Current Specifications Range … WebUsing the 52120A Transconductance amplifier, the 5502E's output current is extended from 20.5 to 120 A; and with the use of 25 and 50 turn coils, it can calibrate instruments requiring currents up to 6000 A. The 5502E also … WebThe 5502A can also measure thermocouples and thermocouple simulators. Two options add the capability to calibrate oscilloscopes to either 300 MHz or 600 MHz. Additionally, with … portable chair for shower

Multi-Product Calibrator Model 5502E by Fluke

Category:Calibrador multiproducto 5502A - Fluke Cal

Tags:Fluke 5502a extended specifications

Fluke 5502a extended specifications

Fluke 5502A Manuals ManualsLib

WebFeb 6, 2024 · Remember, the Fluke 5500A,5520A is no longer manufactured and technical support has been terminated. If you are not going to use scope or PQ options, the E series is cheaper. But it cannot output both volts and current at the same time. Logged Arhigos Regular Contributor Posts: 75 Country: Re: Fluke 5522A Alternatives WebThe 300 MHz and 600 MHz options are not compatible with the 5502E. The 5502E does not have SCOPE and TRIG OUT terminals. The SCOPE and TRIG OUT buttons are on the front panel of the 5502E, but they are non-functional and beep when pushed. Page 12 488.1-1987 and 488.2-1987.

Fluke 5502a extended specifications

Did you know?

WebFLUKE 5502A. The Fluke 5502A Multi-Product Calibrator addresses common workload items like 3.5 and 4.5 digit digital multimeters and more. It comes with internal and external protection features that enable you to transport it easily and perform onsite or mobile calibration. The 5502A can also be fully automated with MET/CAL® Plus Calibration ...

WebKey features Intuitive calibration experience with 17.8 centimeter color touch screen Better match your existing digital multimeter workload with … WebQ Eighty United General Trading & Cont. Co. W.L.L. > Catalog

WebUsing the Fluke Calibration 52120A Transconductance Amplifier, the 5502A’s output current can be extended from 20.5 to 120 A; and with the use of 25 and 50 turn coils, it can calibrate instruments requiring up to 6000 A. The 5502A calibrator covers many of the most common items in your workload, including: • Handheld and bench meters WebThe 5502A Multi-Product Calibrator replaces the 5500A and addresses common workload items like 3.5 and 4.5 digit digital multimeters and more. It comes with internal and external protection features that enable you to transport it easily …

WebThe 5502A calibrator covers many of the most common items in your workload, including: Handheld and bench meters (analog and digital) to …

WebRTDs. The 5502A can also measure thermocouples and thermocouple simulators. Two options add the capability to calibrate oscilloscopes to either 300 MHz or 600 MHz. Using the Fluke Calibration 52120A Transconductance Amplifier, the 5502A’s output current can be extended from 20.5 to 120 A; and with the use of 25 and 50 turn coils, it can irregular heartbeat when to see a doctorWeb5500A Multi-Product Calibrator This product is discontinued. Please see the 5502A Multi-Product Calibrator. Request a replacement Models and Accessories Knowledge and Information Home Products Obsolete Products 5500A Multi-Product Calibrator Request a quote First Name * Last Name * Email Address * Business Phone * Company * Country * portable champagne wallWebFluke 5520A Service Manual Multi-product calibrator Also See for 5520A: Operator's manual (420 pages) , Programmer's manual (46 pages) , Getting started (38 pages) 1 2 3 4 Table Of Contents 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 … portable chairs recliner indoorWebEl calibrador 5502A abarca muchos de los objetos más comunes de la carga de trabajo, entre otros: Multímetros manuales y de banco … irregular noun plural worksheetWebFluke 5700A/5720A Multifunction Calibrators The 5700A/5720A have been discontinued. For a more up-to-date, improved solution, see the 5730A Multifunction Calibrator. Add to request list Highlights Description Specification Models and Accessories Knowledge and information QUOTE portable chairs with umbrellaWebThe Fluke Calibration 5730A High Performance Multifunction Calibrator is the culmination of years of engineering development, customer research and industrial design, to bring to market the new “gold standard” in … portable change room south africaWeb5500A Manual Supplement (Eng) (100.1 KB) 5500A Multi-Product Calibrator Operator Manual. Home. Products. Purchase Info. News. Training and Events. Literature and Education. Service and Support. portable change holder for car